top of page

PROTECTION AND CONTROL · POWER SYSTEM STUDIES · COMMISSIONING

Power system studies, relay protection and commissioning

Optimum Engineering Ltd. models, protects and commissions low- and high-voltage electrical systems for utilities, renewable generation, data centers, and commercial and industrial facilities.

See our projects
Single-line diagram with protective relays

PEO-CERTIFIED ENGINEERING COMPANY · UTILITIES · RENEWABLES · DATA CENTERS · COMMERCIAL AND INDUSTRIAL

WHAT WE DO

Three services, one aim: keep your system safe, coordinated and online

Engineering service

Expert power system studies that support resilient grid planning and optimized operations.

  • Short circuit study

  • Protection device coordination study

  • Arc flash analysis

  • Load flow analysis

  • Ground grid designing

  • Harmonic analysis

  • Power stability and motor starter analysis

  • Low- and medium-voltage cable ampacity and temperature analysis (Neher-McGrath)

Relay protection and SCADA

We calculate, set, test and commission protection systems, and we investigate when something trips.

  • Protection and control solutions, including relay settings calculation and SCADA design and programming

  • Relay protection system testing and commissioning

  • Relay setting configuration and logic development for microprocessor relays

  • Analysis of faults and sequence of events records

  • SCADA testing and verification

  • Electrical equipment testing and commissioning

Project management and designing

We design protection and control upgrades and see them through to energization.

  • Protection and control panel retrofit designing

  • Project management, commissioning and FAT witness testing

  • CAD drawing service

  • SCADA designing

SPECIALIZED SERVICES

Switchgear design, protection settings and AI-assisted predictive maintenance

Low- and medium-voltage switchgear design

Design of low- and medium-voltage switchgear together with its protection and control.

Protection and control settings development

Protection and control settings developed, documented and delivered ready for testing and commissioning.

Predictive maintenance with AI engineering tools

Calculation tools and AI-based engineering solutions for predictive maintenance of electrical equipment.

NEW

ADDED TO OUR SERVICE PORTFOLIO

Low- and medium-voltage cable ampacity analysis, with our own tools

Ampacity and temperature analysis for low- and medium-voltage cables is part of our engineering service. We carry it out with calculation tools developed in-house by Optimum Engineering.

NEHER-McGRATH

Duct bank ampacity

Our calculator for low- and medium-voltage cables in underground duct banks, used in our ampacity and temperature analysis where table values are not enough. Accounts for duct arrangement, burial depth, soil thermal resistivity and load factor.

NEC 310.16

Low-voltage conduit ampacity

Our calculator for low-voltage conductors in conduit, used in our low-voltage cable ampacity analysis. Applies ambient temperature correction and conductor-count adjustment to the table ampacity.

Cross-section of an underground duct bank

Developed and owned by Optimum Engineering Ltd. for use in our engineering service. Validated against commercial ampacity software.

NEW

ADDED TO OUR SERVICE PORTFOLIO

Protection and control solutions

Relay settings calculated and documented for microprocessor relays, together with SCADA design and programming, ready for testing and commissioning.

WHAT WE DELIVER

  • Relay settings calculation

  • Relay setting configuration and logic development

  • SCADA design and programming

  • Settings documented for testing and commissioning

OUR MATLAB SCRIPTS

  • SEL-411L line differential script

  • SEL-487E transformer differential and backup protection script

  • Distance relay settings script

  • Transient and frequency stability script

  • Switchgear design script with AI engineering tools

RELAY MANUFACTURERS WE WORK WITH

SEL

GE

ABB

Siemens

Schneider Electric

Beckwith

and more

SEL-487E transformer differential and backup protection plots

SEL-487E transformer differential and backup protection

SEL-411L line differential alpha plane

SEL-411L line differential: alpha plane and fault simulator

Frequency response after a generator trip

Stability study: frequency response after a generator trip

Distance relay settings tool

Distance relay settings: zones, fault simulation and test waveforms

SELECTED PROJECTS

Generation, data centers and large facilities

Solar arrays at Nanticoke Solar

RENEWABLE GENERATION

Nanticoke Solar, 44 MW

Testing and commissioning of the solar collector system. Nanticoke, Ontario.

Relay test set at a data center switchgear

DATA CENTER

Google data center, Santiago

Protective relay commissioning. Santiago, Chile.

OPG Darlington station buildings
Laptops and test equipment during load bank commissioning

NUCLEAR GENERATION

OPG Darlington nuclear station

Load bank commissioning for the EPG-2 8 MW gas turbine, with Fairway Electric.

Time-current coordination curves

COMMERCIAL

Upper Canada Mall

Arc flash and coordination study for the mall's electrical distribution system.

Touch voltage profile at the main transformer

INDUSTRIAL

Crumb Manufacturing

Grounding design for the manufacturing facility, with a touch voltage profile at the main transformer.

The Well towers in Toronto
Arc flash warning label for The Well, Tower E

COMMERCIAL AND RESIDENTIAL

The Well, Toronto

Arc flash and coordination studies for one of the city's largest condominium complexes.

Building photo: Sikander Iqbal, CC BY-SA 4.0, via Wikimedia Commons.

CLIENTS INCLUDE

Ontario Power Generation · Avangrid · PCL Construction · City of Hamilton, Ontario · Niagara Health System · Electrobauer System Limited · Robertson Electric · CIMA+

Have a study or commissioning scope to price?

Send us your single-line diagram or a short description of the work.

EMAIL

PHONE

519-277-9302

LOCATION

Cambridge, Ontario

Optimum Engineering logo

Optimum Engineering Ltd. · Cambridge, Ontario · 519-277-9302 · guelar@rlyope.com

© 2026 Optimum Engineering Ltd. All rights reserved.

bottom of page